Line Reactors

Line Reactors

Entes ENT.SGR Series line reactors are used between the network and motor drives. Connecting these reactors serially between the network and motor drives provides many benefits to the system.

Advantages;

  • Limits the peaks that occur in the current
  • Prevents drive vibrations
  • Limits harmonic currents
  • Protects the motor drive from high voltages
  • Prolongs the system’s operating life

Product Code
Current (A)
Motor Power (KW)
Cosφ=0,75
Inductance
(mH)
A (mm)
B (mm)
C (mm)
D (mm)
E (mm)
F (mm)
H (mm)
Weight (kg)
ENT.SGR.4.400-5A 5 2,5 5,704 120 61 90 44 100 5*10 125 2
ENT.SGR.4.400-6,3A 6,3 3 4,753 120 61 90 44 100 5*10 125 2,25
ENT.SGR.4.400-8A 8 3,75 3,565 120 61 90 44 100 5*10 125 2,75
ENT.SGR.4.400-10A 10 5 2,852 120 71 110 54 100 5*10 125 3
ENT.SGR.4.400-12,5A 12,5 6 2,377 150 75 110 55 125 5*10 150 3,25
ENT.SGR.4.400-16A 16 7,5 1,901 150 75 110 55 125 5*10 150 4
ENT.SGR.4.400-20A 20 10 1,426 150 90 110 70 150 5*10 150 4,5
ENT.SGR.4.400-25A 25 12 1,188 150 90 110 70 150 5*10 150 5
ENT.SGR.4.400-32A 32 15 0,951 180 94 135 74 150 6*12 181 6
ENT.SGR.4.400-40A 40 18 0,792 240 105 185 80 150 6*12 210 10
ENT.SGR.4.400-50A 50 25 0,570 240 105 185 80 200 6*12 252 13
ENT.SGR.4.400-63A 63 30 0,475 240 125 185 100 200 10*15 252 16
ENT.SGR.4.400-80A 80 37,5 0,380 240 125 185 100 205 10*15 262 20
ENT.SGR.4.400-100A 100 50 0,285 240 140 185 115 205 10*15 262 22
ENT.SGR.4.400-110A 110 55 0,259 240 126 186 106 205 10*15 262 23
ENT.SGR.4.400-125A 125 60 0,238 300 132 224 97 235 10*15 300 24
ENT.SGR.4.400-160A 160 75 0,190 300 157 224 122 255 10*15 325 28
 
*Using any capacitors instead of the indicated capacities may produce unexpected results and issues.